Uniden BCD396XT User Manual

Page 262

Advertising
background image

262

<COMMAND BSP>
Get/Set Band Scope System Settings
Controller → Radio
BSP[\r]
BSP,[FRQ],[STP],[SPN],[MAX_HOLD][\r]
Radio → Controller
BSP,[FRQ],[STP],[SPN],[MAX_HOLD][\r]
BSP,OK[\r]

[FRQ]

: Center Frequency

[STP]

: Search Step

500

: 5k

625

: 6.25k

750

: 7.5 k

833

: 8.33k

1000 : 10k

1250 : 12.5k

1500 : 15k

2000 : 20k

2500 : 25k

5000 : 50k

10000 : 100k

[SPN]

: Sweep Span

0.2M,

0.4M,

0.6M,

0.8M,

1M,

2M,

4M,

6M,

8M,

10M,

20M,

40M,

60M,

80M,

100M,

120M,

140M,

160M,

180M,

200M,

250M,

300M,

350M,

400M,

450M,

500M

[MAX_HOLD]

: Max Hold Display

(0:OFF / 1:ON)


Get/Set Band Scope System Settings.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.

This command is only acceptable in Programming Mode.


<COMMAND GIE>
Get Global IF exchange Frequency
Controller → Radio
GIE [\r]
Radio → Controller
GIE,[FRQ][\r]
GIE,-1[\r]

[FRQ]

: IF Exchange Frequency

(250000-13000000)


This command is used to get Global IF exchange frequency list.
You should call this command again and again to get all global IF exchange
frequencies until the scanner returns "-1".
"-1" means that no more IF exchange frequency exists.
This command is only acceptable in Programming Mode.

Advertising