Connecting ac power, 17 stac6 hardware manual, Ac power plug – Applied Motion STAC6-C User Manual

Page 17

Advertising
background image

17

STAC6 Hardware manual

920-0029 Rev. C

5/2/2012

Connecting AC Power

Using the connector supplied connect to the AC supply per the diagram below. Use 16 AWG wire for Line

(L) and Neutral (N). Use 14 AWG for Earth Ground (G).

Care should always be taken when working with high voltages.

In regions where the single-phase supply is higher, an auto transformer can be used to drop the voltage to

the correct level.

Fusing

The STAC6 contains an internal 8A fast acting fuse. The STAC6-220 contains an internal 3.5A slo-blo (time

delay) fuse. If an external fuse is desired, we recommend a 6A fast acting fuse for the 120V STAC6 and a 5

amp fast acting fuse for the 220V version.

Line Filter

For applications requiring CE EMC compliance, a Corcom 6ET1 line filter is required in series with the AC

input.

To Earth Ground
To Neutral
To Line (Hot)

green

black or bro

wn

white or blue

AC Power Plug

Advertising
This manual is related to the following products: