43 stac6 hardware manual – Applied Motion STAC6-C User Manual

Page 43

Advertising
background image

43

STAC6 Hardware manual

920-0029 Rev. C

5/2/2012

Do not connect the outputs to more than 30VDC. The current through each output terminal

must not exceed 100 mA.

PLC

STAC6-Si
STAC6-QE

12-24 VDC

Power Supply

+

OUT-

OUT+

IN

COM

Connecting output as a sourcing output.

STAC6-Si
STAC6-QE

OUT-

OUT+

5-24 VDC

Power Supply

+

Load

Connecting outputs as a sinking output.

STAC6-Si
STAC6-QE

OUT-

OUT+

1N4935 suppression diode

5-24 VDC

Power Supply

+

relay

Using output to control a relay.

Advertising