33 stac6 hardware manual – Applied Motion STAC6-C User Manual

Page 33

Advertising
background image

33

STAC6 Hardware manual

920-0029 Rev. C

5/2/2012

Connecting Digital Outputs on the IN/OUT1 connector

Front View

X COMMON

X7 / CW Limit

X3 / Enable

X5

X4 / Alarm Reset

Analog IN-

Analog IN+

X2 / DIR-

X2 / DIR+

X1 / STEP +

X1 / STEP -

GND

GND

+5V OUT

Y COMMON

Y3 / FAULT

Y2 / MOTION

Y1 / BRAKE

� �

� �

� �

� �

� �

� �

� �

� �

� �

� �

� �

� �

� �

� �

� �

� �

X6 / CCW Limit

IN/OUT 1

+5V OUT

+12V OUT

GND

GND

All STAC6 drives feature three digital outputs on the IN/OUT 1 connector:

Y1/Brake: controls an electric brake relay, automatically releasing and engaging as the drive requires

Y2/Motion: indicates that the drive has achieved a desired goal, such as a target position

Y3/Fault: closes when a drive fault occurs. The red and green LEDs will flash an error code.

inside STAC-6

14

17

15

16

Y3/FAULT

Y2/MOTION

Y COM

Y1/BRAKE

These outputs can be used to drive LEDs, relays and the inputs of other electronic devices like PLCs and

counters. These outputs can only sink current.

The COM terminal must be tied to power supply (-).