Connecting Digital Inputs on the IN/OUT1 connector

High Speed Digital Inputs

All STAC6 drives include two high speed inputs called STEP and

DIR. They accept 5 volt single-ended or differential signals, up to

2 MHz. Normally these inputs connect to an external controller

that provides step & direction command signals. You can also

connect a master encoder to the high speed inputs for follow-

ing applications. Or you can use these inputs with Wait Input, If

Input, Feed to Sensor, Seek Home and other such commands.

Connection diagrams follow.

STAC6

Stepper

Drive

IN/OUT 1

COM

DIR-

DIR

DIR+

STEP-

STEP

STEP+

Indexer

with

Sourcing

Outputs

Connecting to indexer with Sourcing Outputs

STAC6

Stepper

Drive

IN/OUT 1

+5V OUT

DIR+

DIR

DIR-

STEP+

STEP

STEP-

Indexer

with

Sinking

Outputs

Connecting to Indexer with Sinking Outputs

inside drive

X1/STEP+

X1/STEP-

11

12

IN/OUT1 Connector

X2/DIR+

X2/DIR-

9

10

Advertising