28

STAC6 Hardware manual

920-0029 Rev. C

5/2/2012

Standard Digital Inputs

As we mentioned above, the high speed STEP and DIR inputs are configured for five volt logic. All other

digital inputs are designed for operation between 12 and 24 volts DC. This includes five inputs on the IN/

OUT 1 connector of all drives (X3-X7) and the eight digital inputs on the IN/OUT 2 connector of -Si and -QE

drives only (inputs IN1-IN8).

Single Ended Inputs

The STAC6 drives include single ended, optically isolated input circuits that can be used with sourcing or

sinking signals, 12 to 24 volts. This includes inputs X3-X7 on the IN/OUT 1 connector and inputs IN1 - IN6

on the IN/OUT 2 connector. This allows connection to PLCs, sensors, relays and mechanical switches.

Because the input circuits are isolated, they require a source of power. If you are connecting to a PLC, you

should be able to get power from the PLC power supply. If you are using relays or mechanical switches, you

will need a 12-24 V power supply. This also applies if you are connecting the inputs to the programmable

outputs of another Si product from Applied Motion.

2200

2200

2200

2200

2200

inside IN/OUT1

8

7

6

5

3

4

ST

AC-6

COM

X3/ENABLE

X4/ALRM RST

X5

X7/CW LMT

X6/CCW LMT

STAC6

Drive

+

DIR+

DIR-

STEP+

-

STEP-

+24VDC

Power

Supply

2200
2200

direction switch

run/stop switch

(closed=run)

Using Mechanical Switches at 24 Volts.