7.

Align the drill hole in the joint plate
with the drill hole that is marked
with the desired angle.

Connect them using the Quick
Release Pin (A) and make sure the
pin fits correctly and is locked into
place.

8.

Arrays with a maximal length of
5m (corresponding to an array with
max. 16 x SEQUENZA 10 N/W incl.
flying frame):

Turn all spring bolts (B) by 90° to a
horizontal position (closed), so that
they snap into the guide slot of the
spring bolt enclosure.

The spring bolts have not yet
snapped into the drill hole of the
rear joint plate. The spring bolts,
however, are all set so that they
automatically snap into place when
you fly the array, then creating
a positive connection with the
selected angle position.

Arrays with a length exceeding 5m
(corresponding to an array with
more than 16 x SEQUENZA 10 N/W
incl. flying frame):

Leave the spring bolts (B) in the
vertical position.

9.

Stand the flying frame up vertically
and remove the Quick Release Pins

Advertising