16. Fuse in the SEQUENZA 10 B

To increase the operating safety of the SEQUENZA 10 B, the subwoofers are equipped with
fuses at the signal input. These fuses reduce the risk of consequential damage resulting from
a short circuit (i.e. charred cables / connectors / fire damage).

16.1

Replacing the Fuses

To replace defective fuses, remove the front grille of the SEQUENZA 10 B.

The fuse holder is on the cable of the front connector (Speakon input).

When necessary, only replace the fuse with the following original fuse:
Bussmann S 506-8A, T 250V

17. Connection

Caution

The operating safety and the highest-possible performance is only guaranteed in conjunction
with the K&F Topas or K&F SystemRack.

17.1

Cabling a K&F System Rack