5 series, 5 series 5 series quick reference – XTA 5 Series User Manual

Page 3

Advertising
background image

 

5 Series

5 Series

5 Series Operator’s Manual

Page 3

5 Series

5 Series

5 Series

5 Series Quick Reference


Editing channels :

press channel’s GAIN key. First press accesses

that channel’s gain. To scroll through channel’s parameters, use the
BACK and NEXT keys. Second press accesses last viewed parameter.
Third press will drop back to the default screen.

Accessing menus:

press the MENU key. Use the BACK and NEXT

keys to select the sub-menu required, and enter the sub-menu using the
ENTER key. This applies to all levels of menu. ENTER always
confirms selections.

The Menus and their Contents

GLOBAL MEMORY

GLOBAL MEMORY

GLOBAL MEMORY

GLOBAL MEMORY

Sub-menu: Recall/Store/Erase input, graphic

EQ, dynamic EQ, and crossover settings, or combinations of these.

INPUT SECTION

INPUT SECTION

INPUT SECTION

INPUT SECTION

Sub-menu: Set up input ganging, and GEQ ‘Q’

setting.

CROSSOVER

CROSSOVER

CROSSOVER

CROSSOVER

Sub-menu: Set up or adjust crossover design, including

routing and auto limiter setting. Also set up output ganging.

INTERFACE

INTERFACE

INTERFACE

INTERFACE

Sub-menu: Comms interface setup (RS232 and RS485),

G.P.I. interface configuration, and wireless interface.

SYSTEM

SYSTEM

SYSTEM

SYSTEM

Sub-menu: Used to view unit’s status, and select various

global options such as PEQ ‘Q’ or bandwidth units, delay units, and
output metering point (pre/post mute).

SECURITY

SECURITY

SECURITY

SECURITY

Sub-menu: Used for locking various operations of the

unit, using a 4 digit code.

AES/EBU

AES/EBU

AES/EBU

AES/EBU

Sub-menu: Switch outputs from analogue to digital and

monitor AES input status info. (AES inputs are switched via rear panel.)

DYNAMIC

DYNAMIC

DYNAMIC

DYNAMIC

Sub-menu: Change how gain reduction meters behave.


Notes
The output meters show level, in dB from the limiter threshold, and the
input meters show level from clipping the A-D converters,
pre-gain and all EQ.

When editing DEQ or compressors, meters read downwards and show
gain reduction for each DEQ section or compressor respectively.

The high and low pass crossover filters are defined independently on
each output channel.

To access the limiter attack and release parameters, select “AutoLimiter
TimeCst: No” when designing a crossover.

To swap parametric filter units between bandwidth (‘BandW’) and ‘Q’,
enter

System

System

System

System

Sub-menu, select ‘Filter Q / Bandwidth’, and select

required readout units.

To swap delay time units, enter

System

System

System

System

Sub-menu, select ‘Delay

Time / Distance’, and select required readout units.

Pressing an EDIT key flashes corresponding channels routed to / from
that channel.

Advertising
This manual is related to the following products: