5 Series Operator’s Manual

Security and Locking


After selecting the

Security Sub Menu

Security Sub Menu

Security Sub Menu

Security Sub Menu

and pressing ENTER

ENTER

ENTER

ENTER, select one of the lock types, choosing the most

appropriate one for your application. As ever, ENTER

ENTER

ENTER

ENTER will confirm your selection.

User Specific

User Specific

User Specific

User Specific

Upon pressing ENTER

ENTER

ENTER

ENTER to select this type of lock, each parameter group is presented in turn. Choose the type of lock (as

above) using the FREQ

FREQ

FREQ

FREQ encoder, and press ENTER

ENTER

ENTER

ENTER to confirm each parameter. After the last parameter, the unit

requests a password. The description of this operation is given at the end of this section.
This option allows the user to specify, for each type of parameter, whether it is to be completely accessible (‘No Lock’),
viewable but not adjustable (‘Control’), or effectively unavailable (‘Display’). The ability to operate mutes, store or recall
memories, or even access the menus may also be locked.

Xover Only

Xover Only

Xover Only

Xover Only

All input parameters are available, but only the gain trim (+ 6dB) is available on the outputs, effectively locking all the
crossover settings. All mutes remain active.

Xover + Trim

Xover + Trim

Xover + Trim

Xover + Trim

All input parameters available, but no output parameters – the crossover sections are completely locked. All mutes remain
active.

Xover + Trim + Mute

Xover + Trim + Mute

Xover + Trim + Mute

Xover + Trim + Mute

As for ‘Xover + Trim’ but additionally, output mutes are locked. Input mutes remain active.

Changes Only

Changes Only

Changes Only

Changes Only

All parameters may be viewed, but none may be adjusted. This applies to both inputs and outputs. All mutes remain
active.

Changes + Views

Changes + Views

Changes + Views

Changes + Views

No parameters are accessible – in effect the EDIT

EDIT

EDIT

EDIT keys do nothing. All mutes remain active.

Changes + Mutes

Changes + Mutes

Changes + Mutes

Changes + Mutes

All parameters may be viewed, but none may be adjusted. This applies to both inputs and outputs. All mutes are also
locked.

EVERYTHING

EVERYTHING

EVERYTHING

EVERYTHING

No parameters are accessible – in effect the EDIT

EDIT

EDIT

EDIT and MUTE

MUTE

MUTE

MUTE

keys do nothing.


Entering the Password to Complete the Locking Operation

After selection of the lock type from the list above, a four-digit security code will be asked for. This can be entered by
using the FREQ

FREQ

FREQ

FREQ control to select a character, and the BACK

BACK

BACK

BACK and NEXT

NEXT

NEXT

NEXT keys to move to the next character.


Alternatively, the EDIT

EDIT

EDIT

EDIT keys can be used to enter a code by pressing any combination of the eight buttons. Each EDIT

EDIT

EDIT

EDIT key

represents its channel labelling, so any combination of A

A

A

A, B

B

B

B, C

C

C

C, D

D

D

D, 1111, 2

2

2

2, 3

3

3

3, 4

4

4

4, ((((5

5

5

5, 6

6

6

6

, 7

7

7

7 and 8

8

8

8

)*

)*

)*

)* can be used as a code, as

shown below. Press ENTER

ENTER

ENTER

ENTER to accept code and then re-enter it to confirm.

To prevent external computer control being used to adjust locked settings,
be sure to set the external interface to OFF before locking out the unit.

*DP548 only