Beisler 739-23-1 Program User Manual

Page 15

Advertising
background image

4-15

1.6.5

Testing of step motors

This option allows for the testing of the step motors.

CAUTION!

To complete the test programme, the axes must be referenced.

Operating steps

Insert the setting template into the X-guide of the sewing machine.

Switch to test mode (see chapter 1.6).

Select the test programme by means of the “

” or “

” key.

Press the “OK” key.
The following data is displayed:

Press the “OK” key.
The reference run is started.

After completion of the reference run, the three step motor axes
complete 50 test cycles each.

The control checks whether the reference position has been reached
without step losses. If no step loss has occurred, the display reads as
follows:

If step losses have occurred, the display reads as follows:

The figure before “Err” indicates the axis/axes where a step loss
occurred.

Display

Axis

1

X axis

2

Y axis

3

X and Y axes

4

Z axis

5

X and Z axes

6

Y and Z axes

7

X and Y and Z axes

Press “OK” key.
The system returns to the basic multitest programme.

Advertising