Csat-6070 – Comtech EF Data CSAT-6070 User Manual

Page 23

Advertising
background image

CSAT-6070

C-Band Transceiver

50 and 100 Watt

Transmit

Frequency, RF

6725 to 7025 MHz

6725 to 7025 MHz (Optional Extended)

6725 to 7025 MHz (Optional Wide)

6725 to 7025 MHz (Optional Super
Wide)

Frequency IF

70 MHz ± 18 MHz

140 MHz ± 36 MHz (Optional)

Output Power, P

1Db

(50W)

+47 dBm

(100W)

+50

dBm

Gain

(50W)

74 dB

(100W)

77

dB

Attenuator Range

25 dB in 0.25 dB steps

Gain Flatness

± 0.75 dB full RF band

± 0.75 dB per 36 MHz

Gain Stability

± 0.25 dB at constant C

± 1.00dB from -40° to+55°C (-40 to

131° F)
Carrier Mute

-70 dBc

Intermodulation

-33 dBc for two carriers at 6 dB OPBO from

rated power

Second Harmonic

-55 dBc

Spurious

AC line harmonics

-45 dBc

Carrier related, <500kHz -60 dBc

All other in-band

(50 W) -18 dBm

-65 dBc

(100 W) -15 dBm

-65 dBc

AM to PM Conversion

3.0° at 6 dB OPBO from rated power

RF Output VSWR

1.25:1

RF Output Connector

CPR137G

IF Input Impedance

50 Ohms

IF Input VSWR

1.25:1

IF Input Connector

Type N Female

Receive

Frequency RF

4500 to 4800 MHz

Frequency IF

70 MHz ±18 MHz

140 MHz ± 36 MHz (Optional)

Gain, without LNA

45 dB

Gain Flatness, without LNA

± 0.75 dB full RF band

± 0.75 dB per 36 MHz

Gain Stability, w/o LNA

± 0.25 dB constant temp.

± 1.00 dB -40° to +55°C

Output Power, P1dB

+13dBm

Two Tone Inter-modulation

-50 dBc for two tones at 0 dBm each, 1 MHz

apart

Image Rejection

-60 dBc

RF Input VSWR

1.25:1

RF Input Connector

Type N Female

IF Output Impedance

50 Ohms

IF Output VSWR

1.25:1

IF Output Connector

Type N Female

Common

Conversion

Dual, no spectral inversion

Frequency Step Size

1.0 and 2.5 MHz automatic

Frequency Stability

1x10

-9

/day

1x10

-7

/year

-40° to +55°C

1x10

-8

/Temp

Attenuation

Tx

0-25 dB in 0.25 dB

steps

Rx

0-20 dB in 0.25 dB

steps
Phase Noise

100 Hz

-66 dBc/Hz

1 kHz

-76 dBc/Hz

10 kHz

-86 dBc/Hz

100 kHz

-96 dBc/Hz

Group Delay

Linear

0.1 ns/MHz

Parabolic

0.02 ns/MHz

2

Ripple

1 ns p-p

Monitor and Control

Methods

Both EIA-485 and EIA-232 Serial

Interface
Handheld

controller,

optional

Commands

Set Tx frequency

Set Rx frequency

Set Tx attenuation

Set Rx attenuation

Report Tx output power

Mute

Tx

Report

internal

temperature

Report power supply voltages

Set

time

Set

date

Faults

Upconverter functions

Downconverter

functions

Upconverter

Synthesizers

Downconverter

Synthesizers

Internal Reference oscillator

LNA current fault

Over temperature condition

Environmental

Temperature

-40° to +55° C (-40 to 122° F) Operating

-50° to +75° C (-90 to 135° F) Storage

Altitude

15,000 ft, mean sea level

Humidity

0 to 100 Percent, Relative

Prime Power

90 to 260 VAC Standard

47 to 63 Hz Standard

48 VDC Optional

Dimensions:

50 W

9.75H x 10W x 23D inch

(24.77H x 25.4W x 58.42D cm)

100 W

10 H x 12.5W x 26D inch

(25.4H x 31.75W x 66.04D cm)

Weight:

50 W

65 lbs (29 kg)

100 W

80 lbs (40 kg)

Low Noise Amplifier

45° K, non-isolated


2 11 4 Wes t 7t h St. Tem pe , A Z 8 5 2 8 1 U S A

Tel. ( 4 8 0 ) 33 3 - 2 2 0 0 . F a x ( 4 8 0 ) 3 33 - 2 5 4 0

e m a i l :

s a l e s @ c o m t ec h e f d a ta . c o m

w w w. c o m t e c h e f d a ta. c o m

Comtech EF Data reserves the right to make changes to specifications of products described in this

data sheet at any time without notice and without obligation to notify any person of such changes.

© 2001 Comtech EFData (Part Number DS/CHP1.DOC) 12/21/01

Advertising