Chapter 3. SYSTEM OPERATION



3.1 Pin-outs..................................................1
3.2 Turning On the CSAT ............................3
3.3 Configuring the CSAT ............................3



This section contains instructions for operating the CSAT-6070, 50 Watt C-Band
Transceiver. The Primary customer interface to the CSAT is via the Remote
Communications port. Appendix A provides details regarding the protocol and
command/response structure used on this interface. This section will define in
detail the controllable parameters provided via the command/response structure.

3.1 P

IN

-

OUTS

3.1.1 C

ONNECTOR

J3: AC

P

OWER

, M

AINS

, 100

TO

125 VAC,

OR

205

TO

240

VAC.

WARNING

To avoid a serious shock hazard, correctly determine the mating connector type
in use and wire it according to the following table:

EARLY UNITS

NEWER UNITS

Pin Mating

Connector

Type

KPT06J12-3S
MS3116J12-3S

Mating Connector Type
CA3106E18-22SB

A Line

Ground

B Ground

Neutral

C Neutral

Line

3-1