Mechanical interface, B.1.1.8 r, If i – Comtech EF Data CSAT-6070 User Manual
Page 88: J9 – j11, B.1.2 m
Advertising
50 Watt C-Band Transceiver
Revision 0
Redundant Systems
MN/CSAT607050.IOM
B.1.1.8 R
X
IF I
NTERFACES
, J9 – J11
The Rx IF output signal is fed to the customers equipment from the RSU-5060 at
connector J9. The RSU-5060 contains a power combiner which takes the IF input
signals from both CSAT A and CSAT B via the J10 and J11 connectors and
provides a single output signal at J9. The IF output power at J9 will nominally be
3dBm less than the IF input power at either J10 or J11.
B.1.2 M
ECHANICAL
I
NTERFACE
The RSU-5060 is housed in a weather resistant, sealed aluminum housing with
five external circular connectors and six Female N-Type connectors. The
mechanical dimensions and mounting interface are shown in Chapter 1
B-6