Rsu-5060 operation, Peration – Comtech EF Data CSAT-6070 User Manual

Page 89

Advertising
background image

50 Watt C-Band Transceiver

Revision 0

Redundant Systems

MN/CSAT607050.IOM


B.2 RSU-5060 O

PERATION

The RSU-5060 is designed to provide single-point control for both the Tx and Rx
transfer switches (Waveguide Switches). In addition, the RSU-5060 provides the
customer with a single interface connection to his M&C system. Through this
interface the customer can access and control all configuration, monitor and faults
status parameters of both CSAT’s. The RSU-5060 is a ‘smart box,’ the unit
contains a microcontroller running algorithms to process status and command
information from the two CSAT’s and control the Tx and Rx waveguide switches
accordingly. A functional block diagram of the RSU-5060 is shown in Figure
B-2.

RS485 Tx+
RS485 Tx-
RS485 Rx+
RS485 Rx-

RS485 Tx+
RS485 Tx-
RS485 Rx+
RS485 Rx-

RS485 Tx+
RS485 Tx-
RS485 Rx+
RS485 Rx-

Micro

Controller

A AUXCOM Td

A AUXCOM Rd

B AUXCOM Td

B AUXCOM Rd

RS232 line
Drives and

Recievers

&

Multiplexer

Td
Rd

a

b

c

A FAULT N.O.

REDUNDANCY A*

POSITION A*

REDUND_FLT*

B FAULT N.O.

REDUNDANCY B*

POSITION B*

REDUND_FLT*

B SELECT*

CSAT A

+24 VDC

CSAT B

+24 VDC

Rx

TRANSFER

SWITCH

Tx

TRANSFER

SWITCH

POS A CMD

POS B CMD

POS A IND

POS B IND

POS A CMD

POS B CMD

POS A IND

POS B IND

Signal

Conditioning

RED AUTO/MAN

SWITCH CMD

A ONLINE CLOSED

B ONLINE CLOSED

A FAULT OPEN
B FAULT OPEN

Customer

Monitor

&

Control

RSU-5060

Figure B-2 RSU-5060 Functional Block Diagram

B-7

Advertising