Comtech EF Data CSAT-6070 User Manual
Page 49
50 Watt Model C-Band Transceiver
Revision 0
Installation
MN/CSAT607050.IOM
Figure 2-23. Pipe Blocks
Figure 2-24. Looking down at Pipe Blocks
8. 6. Attach bracket (5, figure 2-1) to the strap (4) using two nuts (10), two flat
washers, (7), and two splitlock washers (8).
9. Place the assembly against the pole with the strap around the pole and trim
the strap (4) to fit as shown in Figure 2-23, using the tin snips.
10. Attach bracket (3, figure 2-1) to the strap (4) using two nuts (10), two flat
washers (7), and two splitlock washers (8).
11. Slide tensioner bracket (2) into channel of the top unistrut bracket (1).
12. Place assembly on the pole.
13. Slide bracket (3) over bracket (2).
14. Place flat washer (7) and splitlock washer (8), and nut (10) on bracket (2).
2-25