System Operation

MN/CSAT607050.IOM

3.3.17 R

EDUNDANCY

C

ONTROLLER

T

OGGLE

The User can cause the RSU-5060 Redundant Switch Unit to switch the position
of both the Tx and Rx transfer switches using this command.

• If the RSU-5060 is in AUTO mode, the command will only cause a

switchover if the OFFLINE unit is currently UNFAULTED.


• If the RSU-5060 is in MANUAL mode, the command will cause a

switchover independent of the state of the OFFLINE unit.

Associated Remote Command(s):

RTG=

Example(s): RTG=

3.3.18 S

ET

P

HYSICAL

A

DDRESS

The Remote (Physical) address to which the CSAT will respond can be set to any
value between 0001 and 9999. (The factory default is 0001)

Associated Remote Command(s):

SPA=

Example(s): SPA=0001

3.3.19 S

ET

B

AUD

R

ATE

The Baud Rate of the communication port, J5, can be set to any values shown
below:

1200, 2400, 4800, 9600, 19200, 38400 (The factory default is 9600)

Associated Remote Command(s):

SBR=

Example(s): SBR=9600




3.3.20 S

ET

D

ATE

The CSAT contains a battery powered Real Time Clock (RTC) used to provide
Date/Time stamping of events, alarms and faults. The date can be changed by the
user.

Associated Remote Command(s):

DAY=

3-9