Pbio register mapping to shotlist location, Trigger – DNF Controls 2034CL-L-PBIO VS.3.0 User Manual

Page 12

Advertising
background image

12

2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO

Option

9.

PBIO REGISTER MAPPING TO SHOTLIST
LOCATION

Register 0-30 Î

Cue Point 0-30

Register 31-60 Î Cue

Point

101-130

Register 61-90 Î Cue

Point

201-230

Register 91-99 Î Cue

Point

301-309


10. TRIGGER

The operator fires a trigger using the Timeline or Run function on the production switcher. The
ST300 puts the Video Server into the following modes based on the trigger value:

GRASS VALLEY GROUP

Trigger

Value

Mode

0

Play

1

Recue to beginning of clip

2

Slo-mo

using

ST300

Preset

Speed

3

Reverse

Play

4

Still

Frame

5

Play

6

Record

7 or greater

Play

SONY

Trigger

Value

Mode

0

Recue to beginning of clipPlay

1

Play

2

Slo-mo

using

ST300

Preset

Speed

3

Reverse

Play

4

Still

Frame

5

Play

6

Record

7 or greater

Play


To control more than one VTR, enable the Peripheral Device Address for the required VTRs. The
Trigger will be sent to the enabled devices.
OR

GANG the required VTRs on the ST300. See the Menu Table for GANG instructions. Enable the
Peripheral Device Address for one of the GANGed VTRs. The Trigger will be sent to the enabled
VTR. The other VTRs in the GANG will perform the same action.