System installation, A. shotbox, B. st300 controller – DNF Controls 2034CL-L-PBIO VS.3.0 User Manual

Page 6

Advertising
background image

6

2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO Option

3. SYSTEM

INSTALLATION

a.

SHOTBOX


1)

Plug one end of a standard 9-pin, RS422 serial cable into the OUTPUT
connector on the rear of the SHOTBOX. Plug the other end of the
cable into the AUX connector on the rear of the ST300.


2)

Connect the 5 VDC, 1Amp POWER SUPPLY into the POWER connector on
the rear of the SHOTBOX. Plug the POWER SUPPLY into an outlet, 90 VAC
to 240 VAC.

b. ST300

CONTROLLER

1)

Plug one end of a 9-conductor, RS422 serial cable into the VTR 1 (2, 3 or 4)
connector on the rear of the ST300. Plug the other end of the cable into the
9-pin REMOTE connector on the Video Server.


2)

Connect the +5, +12, -12 VDC POWER SUPPLY into the POWER connector
on the rear of the ST300. Plug the Power Supply into an outlet, 90 VAC to 240
VAC.


3)

Assign logical Louth ports to ST300’s VTR connectors.


a) Press

[MENU].


b)

Turn the Wheel until VTR Louth Address is displayed.


c)

Press

VTR[1], VTR[2], or VTR[3] to select VTR.

d)

Assign a Louth Port address for that VTR 0-9. (0 turns that channel
OFF.)


e)

The second line of the display will show “Input=Enter, Out=ESC”


f)

Press

[ENTER] to select an Input Port.

(A “-“ will appear in front of the selected number.)

OR


[ESC] to select an Out Port.

g)

Repeat steps c-f to assign a Louth Address to ALL VTRs you want to
use.


h)

Press

[ESC] to leave the MENU mode.


4)

Check the other options in the SETUP MENU prior to using the ST300 to
confirm proper Record mode and other User settable modes.