Installing optional controls, Millivolt wiring diagram, Electronic ignition wiring diagram – Desa (V)CB36N(E) User Manual

Page 13: Wiring diagrams, Continued

Advertising
background image

www.desatech.com

117437-01B

13

Figure 20 - Millivolt Ignition Wiring Diagram

Figure 21 - Electronic Ignition Wiring Diagram

TH
TP
TH/TP

WHITE

RED

DO NOT

CONNECT

TO 120V

HIGH LIMIT

SWITCH

N

O

T

O

L

P

FF

O

I

NC

Pilot
Burner

Incoming
Main Gas
Supply

Thermocouple

Wall Switch/Remote Receiver

Replace factory wiring with
105° C equivalent or higher rating

External wiring use only Class 2
thermostat wire 18 Ga. Red/White

Millivolt Wiring Diagram

WIRING DIAGRAMS

NOTICE: This appliance is equipped with a vent safety shutoff switch

which will shut down the appliance in case of a venting problem. Do

not bypass the vent safety shutoff switch. If the appliance should

shut down, have a qualified installer, service agency, or your gas

supplier inspect the vent before operating.

CAUTION: label all wires prior to disconnection when servicing

controls. Wiring errors can cause improper and dangerous opera-

tion. Verify proper operation after servicing.

EV2

EV1

High Limit

Switch

Gas Valve

Orange

Red

Red

Transformer

Ignition Control

Module

Black

Black

Ground

120 VAC

White

24
V

A

C

Blue

Blue

High Voltage

MV PV

TH P/MV GND

TR

Green

Ignition Module

ELECTRONIC IGNITION

WIRING DIAGRAM

Black

Pilot Burner

Ignitor

NC

INSTALLING OPTIONAL CONTROLS

Continued

Advertising