Operating fireplace – Desa (V)CB36N(E) User Manual

Page 20

Advertising
background image

www.desatech.com

117437-01B

0

OPERATING FIREPLACE

Continued

MANUAL LIGHTING

PROCEDURE

1. Remove glass door (see Removing/Replacing

Glass Door, page 17).

2. Follow steps 1 through 8 under Lighting

Instructions, page 19).

3. Press gas control knob and light pilot with

match.

4. Keep gas control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release gas

control knob. Follow steps 10 through 11 under

Lighting Instructions, page 19).

5. Replace glass door (see Removing/Replacing

Glass Door, page 17).

ELECTRONIC IGNITION

SySTEM

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information, col-

umn 1, page 19.

2. Turn off all electrical power to the fireplace.

3. Turn wall switch to the OFF position.

4. Open lower louver panel.

5. Turn equipment shutoff valve clockwise

to the OFF position (see Figure 34).

Do not force.

6. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information, column 1, page 19. If

you don’t smell gas go to the next step.

7. Turn equipment shutoff valve counterclock-

wise

to the ON position. Do not force.

8. Close lower louver panel.

9. Turn on all electric power to the fireplace.

10. Turn the wall switch to the ON position.

11. Visually locate the pilot. The ignitor should

begin to spark and the main burner should

ignite once flame appears at pilot.

• If lighting the appliance for the first time

each season, it may take several attempts

before the supply gas can reach the pilot

and main burner.

• If the appliance will not stay lit after sev-

eral attempts, follow the instructions To

Turn Off Gas To Appliance, and call your

service technician or gas supplier.

TO TURN OFF GAS

TO APPLIANCE

1. Turn off the wall switch.

2. Turn off all electric power to the appliance

if service is to be performed.

3. Open lower louver panel.

4. Turn equipment shutoff valve clockwise

to OFF. Do not force.

5. Close lower louver panel.

Figure 35 - Pilot

Pilot
Burner

Ignitor

Sensor
Rod

OPTIONAL WIRELESS

REMOTE OPERATION

Note:

The WRC receiver and hand-held remote

control kit must be purchased separately (see

Accessories, page 34). Follow installation in-

structions included with the remote control.

1. Turn equipment shutoff valve to ON posi-

tion. You can now turn the burner on and

off with the hand-held remote unit.

IMPORTANT: Be sure to press the ON/OFF

buttons on the hand-held remote control

unit for up to 3 seconds to assure proper

operation.

2. Press the ON/OFF button to turn the

burner on and off.

Figure 34 - Turning Equipment Shutoff

Valve to the OFF Position

NOTICE: During initial operation

of a new heater, the burning of

residues from the manufacturing

process of the firebox and logs

will produce a paper-burning smell

and orange flames. Open a window

for the first few hours of operation

to adequately vent this smell.

Advertising