Operating fireplace, Continued, Optional hand-held remote operation – Desa (V)CB36N(E) User Manual

Page 21: Optional gwms2 on/off wall mounted switch

Advertising
background image

www.desatech.com

117437-01B

1

OPERATING FIREPLACE

Continued

OF

F

PIL

O

T

LO

IH

ON

OFF

REMOTE

ON

OFF

O

N

Blower Control Knob
(Optional Accessory)

Variable
Control Knob

Selector Switch in
Remote Position

Gas Control Knob
in ON Position

Figure 36 - Setting the Selector Switch,

Gas Control Knob and Variable Control

Knob for Remote Operation

OPTIONAL HAND-HELD

REMOTE OPERATION

Note:

All remote control accessories must be

purchased separately (see Accessories, page

34). Follow instructions included with the

remote control.

NOTICE: You must light the pilot

before using the hand-held re-

mote control unit. See Lighting

Instructions, page 20.

After lighting, let pilot flame burn for about

one minute. Turn control knob to ON position.

Adjust flame adjustment knob anywhere be-

tween HI and LO. Slide the selector switch to

the REMOTE position (see Figure 36). Note:

The burner may light if hand-held remote was

on when selector switch was last turned off.

You can now turn the burner on and off with

the hand-held remote control unit.
IMPORTANT:

Do not leave the selector switch

in the REMOTE or ON position when the pilot

is not lit. This will drain the battery.

TO UNLOCK

press both buttons together

on hand-held remote control until the light

stops flashing. The hand-held remote is now

unlocked.

Figure 37 - On/Off Hand-Held Remote

Control Unit HRC100

Control

Button

Indicator

Light

ON/OFF SERIES MODEL HRC100

Hold the control button on the hand-held

remote until burner turns on. Hold the con-

trol button again until burner turns off (see

Figure 37).
TO LOCK

press both buttons on hand-held

remote control until light stops flashing. Hand-

held remote control is now locked. If the fire is

on it will be turned off automatically. In the

locked state, the light will not light up when

any button is pressed.

OPTIONAL GWMS2

ON/OFF WALL

MOUNTED SWITCH

WARNING: Do not connect

the appliance gas controls to a

120 VAC power source. Damage

or injury may occur.

Light the fireplace as instructed in Lighting

Instructions on page 20 . If using an HRC re-

mote with a wall switch, set the remote selector

switch to the ON position (see Figure 36). The

wall switch may now be used to turn the burner

flame ON and OFF.

To turn the fireplace off, turn the wall switch

and/or remote selector switch to the OFF posi-

tion and turn the gas control knob back to

PILOT. The pilot will remain lit.
IMPORTANT:

To turn the pilot off, turn the

gas control knob on the heater to the OFF

position.

Advertising