Pre-installation preparation – Desa (V)CB36N(E) User Manual

Page 6

Advertising
background image

www.desatech.com

117437-01B



• A hearth extension is not required with this

appliance. If one is installed, it is for aesthetic

purposes only and does not have to meet stan-

dard requirements for hearth extensions.

• If you plan on installing a television or entertain-

ment center recessed above your fireplace, it is

recommended that you maintain a minimum 18"

(45.7 cm) above the top of louver opening.

• When locating the termination cap, it is impor-

tant to observe the minimum vent height and

clearances required under code, see Venting

Installation Instructions, page 8.

• Do not recess termination cap into a wall or

siding.

• You may paint the termination cap with 450° F

(232° C) heat resistant paint to coordinate with

the exterior finish.

PACKAGING AND REMOVAL

The (V)CB36 vented decorative gas fireplaces are

packaged with the following items:

• one box containing a 4 piece log set located on

the burner in the firebox.

• one bag containing the owner’s manual with

installation instructions, operator’s guide, and

warranty information.

• one bag of glowing ember material.

• one bag of vermiculite hearth treatments.

1. Remove shrink wrap securing 2 carton trays

to unit.

2. Lift top carton tray off and remove four corner

posts.

3. Discard bottom tray once unit is moved into

position.

PRE-INSTALLATION

PREPARATION

Continued

Note:

To prevent damage to ceramic logs and

glass panels you may want to remove them before

positioning and framing the unit. To access firebox,

see Louver Panels and Glass Door, page 16.

CLEARANCES

Minimum clearances to combustibles for fireplace:

Back, Sides, Floor and Top 0" (0 mm)
Perpendicular walls

10" (25.4 cm)

Ceiling to Louver & Front 36" (91.4 cm)
B-Vent Surfaces

1" (26 mm) (See

venting instructions

for specifics on vent

clearances.)

Mantel Clearances

(See Mantel Clear-

ances, page 7, for

specific clearances to

combustible mantels.)

Combustible material with a maximum thickness

of 5/8" (16 mm) may be flush with top and sides

of front face of fireplace.

FRAMING AND FINISHING

Figure 5 shows typical framing of this fireplace.

Figure 6, page 7, shows framing for corner instal-

lation. All minimum clearances must be met.

For overall unit dimensions, framing allowances

and vent collar locations, see Unit Dimensions,

Figure 7 on page 7.

For available accessories for this fireplace, see

Accessories, page 34. If you are using a separate

combustible mantel piece, refer to Figures 8 and

9, page 8, for proper height and clearances. You

can install a noncombustible mantel at any height

above the fireplace opening.
Note:

Noncombustible mantels may discolor!

Figure 4 - Unpacking Fireplace

Carton
Tray

Glass
Panel

Log
Carton

Corner
Post

Figure 5 - Framing Clearances for Flush

Wall Installation

3"
(91.4 cm)

3

1

/

4

"

(9.1 cm)

14

3

/

4

"

(37.5 cm)

Advertising