This appliance may be vented through a manu-

factured chimney liner system if all are listed,

inspected and approved by local codes and/or

building authorities.

The examples shown in Figure 10 are typical of

most B-vent installations and code practices.

WARNING: This gas fireplace

and vent assembly must be vented

directly to the outside. The venting

system must NEVER be attached

to a chimney serving a separate

solid fuel burning appliance.

Example 1:

Shows the minimum allowable system

height and lateral offset for a 60° or greater inclina-

tion. Code specifies that offsets at 60° or greater

are considered horizontal and must follow the 75%

rule for lateral to total vertical system height. Codes

also allows only one offset in the total system when

at 60° or greater. The total vertical height in this

example represents the minimum height of 8 feet

and therefore the allowable lateral is 6 feet when the

75% rule applies. If the lateral length must exceed

75% then the system must be sized in accordance

with the Category I venting tables.

Example 2:

Shows multiple offsets each at 45°

of inclination. Multiple offsets are permitted if

they do not exceed 45° of inclination. The total

lengths of the two offsets are not required to meet

the 75% rule.

Example 3:

Shows a single offset at 45° of inclina-

tion and therefore the lateral length at 10 feet of offset

does not have to meet the 75% allowable rule.

In each case the offsets must be supported and

firestops must be positioned wherever the vent

must pass through a sub-floor, ceiling joist or

an attic overhang. The vent pipe must terminate

vertically into a listed type vent cap and extend a

sufficient height through an approved roof flash-

ing, roof jack or a roof thimble. At all points the

listed clearances must be maintained.

Vent terminations must be located in accordance

with height and proximity rules of NFPA No. 54 or

CAN/CSA B149. These rules apply to vents at 12"

diameter or less and require a minimum height in

accordance with the roof pitch and a minimum of

8 foot distance from a vertical wall or obstruction

(see Figure 11, page 10).

If venting horizontally through a side wall be-

comes necessary, a listed thimble approved for use

with B-type vent must be used. Check with your

local codes before venting through a side wall.

Some codes areas allow the use of existing B-type

vent systems if the system is at or above the recom-

mended diameter of the flue.

The flue connection must be made using listed B-type

connectors and the existing system must be code

inspected for damage and proper installation.

It is not recommended that this appliance be

common vented with and existing gas burning

appliance. However, if it becomes necessary to

common vent the appliance. The venting system

must be sized and configured in accordance with

the common venting guides Appendix G of the cur-

rent National Fuel Gas Code NFPA No. 54/ANSI

Z223.1 and in Canada with CAN/CSA B149.
Note:

Before connecting this appliance to an

existing vent system or a common venting sys-

tem consult with your local architect planner, or

building official.

Figure 10 - Typical B-Vent Configuration

Maintain

Listed

Clearance

Maintain

Listed

Clearance

12' Min.

12' Min.

45°

45

6'

8'

12' Min.

60

45

Position

Firestop

Position

Firestop

Position

Firestop

Listed

Vent Cap

Listed

Vent Cap

Listed

Vent Cap

Maintain

Listed

Clearance

Maintain

Listed

Clearance

Maintain

Listed

Clearance

Maintain

Listed

Clearance

Support Each

Lateral At

Least Every

6 Feet

Maintain

Listed

Clearance

10'

EXAMPLE 3

EXAMPLE 2

EXAMPLE 1

VENTING INSTALLATION

Continued