Inspecting burners – Desa (V)CB36N(E) User Manual

Page 22

Advertising
background image

www.desatech.com

117437-01B



INSPECTING BURNERS

Check pilot flame pattern and burner flame pat-

terns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper

flame height. Alterations may have occurred dur-

ing shipping and handling. Call a qualified service

person to readjust the pilot if necessary.

The position and pattern of the pilot flames in rela-

tion to the sensing devices should be as shown in

Figures 38 and 39 respectively.

The pilot flame may need adjustment in order

for the thermocouple, thermopile and/or ignition

system to sense the pilot flame.

If your pilot assembly does not meet these re-

quirements:

• turn fireplace off (see To Turn Off Gas to Ap-

pliance, page 19 or 20)

• see sections under Troubleshooting, page 25

Thermocouple

Thermopile

1/4"

Pilot Burner

Piezo
Ignitor

Figure 38 - Pilot Assembly

(Millivolt Ignition System)

3/8" to 1/"

Sensor
Rod

Pilot
Burner

Piezo
Ignitor

Figure 39 - Pilot Assembly

Electronic Ignition System)

BURNER FLAME PATTERNS

Burner flames will be steady, not lifting or float-

ing. Flame patterns will differ from unit to unit

and will vary depending on installation type and

weather conditions.

If vent configuration is installed incorrectly, flames

will lift or “ghost”. This can be dangerous. Inspect

flames after installation to ensure proper installa-

tion and performance. Figure 40 shows a typical

flame pattern.

If burner flame pattern differs from that de-

scribed:

• turn fireplace off (see To Turn Off Gas to Ap-

pliance, page 19 or 20)

• see Troubleshooting, page 25

Figure 40 - Typical Flame Pattern

Figure 41 - Adjusting Air Setting

AIR ADjUSTMENT SETTING

The main burner air shutter opening is factory set

to the following:

Natural Gas - 1/8", Propane/LP Gas - 3/4"

The air shutter may require adjustment depending

on altitude, venting condition, burner operation

and general flame appearance.

If flames are lifting or sooting the shutter may

require opening. If flames are too blue or improp-

erly lighting the shutter may require closing. See

Figure 41 for proper air adjustment.
IMPORTANT:

Do not reduce air shutter opening

any lower than designed minimum stop setting

of 1/8".

1/8" Minimum
Air Opening

Air
Shutter

Burner
Tube

Adjustment
Screw

Advertising