LOGS

• If you remove logs for cleaning, refer to In-

stalling Logs and Glowing Embers, page 18,

to properly replace logs.

• Use a vacuum cleaner to remove any carbon

buildup on logs.

• Replace log(s) if broken. See Replacement

Parts, page 34.

• Replace ember material periodically as needed.

See Replacement Parts, page 34.

CLEANING AND

MAINTENANCE

Continued

VENTING SYSTEM

Conduct annual inspection of the venting system

following these guidelines:

1. Check areas of venting system that are ex-

posed to the weather corrosion (rust spots or

streaks and in extreme cases, holes). Have

these items replaced immediately by a quali-

fied service person.

2. Remove the vent cap and shine a flashlight

into vent. Remove any foreign material.

3. Check for evidence of excessive condensation.

Continuous condensation can cause corrosion

of caps, pipes and fittings and can be caused

by having excessive lateral runs, too many

elbows or exterior portions of the system being

exposed to cold weather.

4. Inspect joints to verify that no pipe section

or fitting has been distributed and loosened.

Check mechanical supports such as wall straps

for rigidity.

SPECIFICATIONS

(V)CB36N

• Maximum Input Rating: 18,000 Btu/hr

• Gas Type: Natural

• Orifice Size (Main Burner): #45 DMS (0.082")

• Ignition: Millivolt

• Manifold Pressure: 3.5" w.c. (0.87 kPa)

• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)

(V)CB36P

• Maximum Input Rating: 18,000 Btu/hr

• Gas Type: Propane/LP

• Orifice Size (Main Burner): #55 DMS (0.052")

• Ignition: Millivolt

• Manifold Pressure: 10" w.c. (2.5 kPa)

• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)

(V)CB36NE

• Maximum Input Rating: 18,000 Btu/hr

• Gas Type: Natural

• Orifice Size (Main Burner): #45 DMS (0.082")

• Ignition: Electronic

• Manifold Pressure: 3.5" w.c. (0.87 kPa)

• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)

(V)CB36PE

• Maximum Input Rating: 18,000 Btu/hr

• Gas Type: Propane/LP

• Orifice Size (Main Burner): #55 DMS (0.052")

• Ignition: Electronic

• Manifold Pressure: 10" w.c. (2.5 kPa)

• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)

ALL MODELS

• Fireplace Dimension HxWxD (Actual size of firebox measurements do not include

nailing flanges or standoffs): 35.75" x 36.25" x 14.75" (90.8 x 92.1 x 37.5 cm)

• Carton Dimension HxWxD: 36.75" x 38" x 16.25" (93.3 x 96.5 x 41.3 cm)