Fireplace installation – Desa (V)CB36N(E) User Manual

Page 16

Advertising
background image

www.desatech.com

117437-01B

1

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 25).

2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas fireplace or opening main gas

valve located on or near gas meter for natural

gas fireplace or using compressed air.

3. Check all joints from propane/LP supply tank

or gas meter to equipment shutoff valve (see

Figure 26, for propane/LP or Figure 27, for

natural gas). Apply noncorrosive leak detec-

tion fluid to all joints. Bubbles forming show

a leak. Correct all leaks at once.

FIREPLACE INSTALLATION

Continued

Figure 25 - Equipment Shutoff Valve

Open

Closed

Equipment
Shutoff Valve

Figure 26 - Checking Gas Joints for

Propane/LP Gas Fireplace

Propane/LP
Supply Tank

Gas Valve

Equipment Shutoff Valve

Figure 27 - Checking Gas Joints for

Natural Gas Fireplace

Gas
Meter

Gas Valve

Equipment
Shutoff
Valve

PRESSURE TESTING FIREPLACE GAS
CONNECTIONS

1. Open equipment shutoff valve (see Figure 25).

2. Open propane/LP supply tank valve for pro-

pane/LP fireplace or main gas valve located on

or near gas meter for natural gas fireplace.

3. Make sure control knob of fireplace is in the

OFF position.

4. Check all joints from equipment shutoff valve

to gas valve (see Figure 26, for propane/LP

or Figure 27, for natural gas). Apply non-

corrosive leak detection fluid to all joints.

Bubbles forming show a leak. Correct all

leaks at once.

5. Light fireplace (see Operating Fireplace, page

19). Check all other internal joints for leaks.

6. Turn off fireplace (see To Turn Off Gas to

Appliance, page 19 or 20 depending on your

model).

LOUVER PANELS AND GLASS
DOOR

CAUTION: Do not operate

this fireplace with a broken glass

door panel or without the glass

door panel securely in place.

For replacement part informa-

tion see Replacement Parts,

page 34.

CAUTION: Wear gloves and

safety glasses while handling

or removing broken glass. Do

not remove if glass is hot. Keep

children and pets away from

glass.

WARNING: If fireplace has

been running, turn off and un-

plug fireplace. Let cool before re-

moving glass door or louvers.

Advertising