Troubleshooting – Desa (V)CB36N(E) User Manual

Page 27

Advertising
background image

www.desatech.com

117437-01B

7

TROUBLEShOOTING

Continued

POSSIBLE CAUSE

1. Turning gas control knob to

HI position when burner is

cold

2. Air in gas line

3. Dirty or partially clogged

burner orifice

1. Flame impingement on logs

2. Debris around burner air

mixer

1. Metal expanding while heat-

ing or contracting while

cooling

1. Battery is not installed or

battery is power is low

1. High or gusting winds

2. Low line pressure

3. Pilot is partially clogged

4. Improper or restricted venting

5. Clogged burner tube, blocked

orifice or improper burner air

adjustment

6. Bad thermopile or thermo-

couple

7. Vent cap improperly installed

or blocked

OBSERVED PROBLEM

Heat produces a whistling noise

when burner is lit

Glass soots

Fireplace produces a clicking/

ticking noise just after burners

are lit or shut off

Remote does not function

Fireplace shuts off in use.

Burner backfiring during com-

bustion

REMEDY

1. Turn gas control knob to LO

position and let warm up for a

minute

2. Operate burner until air is

removed from line. Have gas

line checked by pro pane/LP

or natural gas company

3. Clean burner (see Cleaning

and Maintenance, page 23) or

replace burner orifice

1. Adjust the log set so the flame

does equipment shutoff valve

2. Inspect the opening at the base

of the burner to see that it is

not packed with any type of

material

1. This is normal. If noise is

excessive, contact qualified

service person

1. Replace 9-volt batteries in

receiver and remote control

1. Fireplace has been tested for

up to 40 mph winds. However,

extreme conditions may occur.

See Lighting Instructions,

page 19 or 20

2. Check local propane/LP or

natural gas company

3. Clean pilot (see Cleaning and

Maintenance, page 23)

4. Locate and correct all vent

conditions (see Checking for

Proper Venting, page 10)

5. Clean burner tube and orifice,

adjust air shutter (see Inspect-

ing Burners, page 22)

6. Replace faulty components

7. Check for proper installation

or remove debris or blockage

Advertising