Installation precautions, Venting installation, Pre-installation preparation – Desa (V)CB36N(E) User Manual

Page 8

Advertising
background image

www.desatech.com

117437-01B

8

Figure 9 - Clearances for Combustible

Mantels

Figure 8 - Side Clearances for

Combustible Mantels

PRE-INSTALLATION

PREPARATION

Continued

1

1

/

2

"

(3.8 cm)

3

1

/

2

"

(8.9

cm)

Outer

Surround

Combustible

Material May

Be Used

Perpendicular

Side Wall

5

1

/

4

"

(13.3 cm)

1

3

/

4

"

(4.4 cm)

To Fireplace

Opening

10" (25.4 cm)

33°

Safe

Zone

Ref. Mantel Depth Ref.

Mantel from

Top of Louver

Opening

1

1" (40. cm)

A

18" (45.7 cm)



14" (35. cm)

B

1" (40. cm)

3

1" (30.5 cm)

C

14" (35. cm)

4

10" (5.4 cm)

D

1" (30.5 cm)

5

8" (0.3 cm)

E

10" (5.4 cm)



4" (10. cm)

F

8" (0.3 cm)

7

" (5.1 cm)

G

" (15. cm)

C

B

A

D

E

F

G

Top of Louver

Opening

3

2

1

4
5
6

7

Stud Wall

4" B-Vent
Flue Pipe

2 x 4 Header
at 1" Min.
Clearance

INSTALLATION

PRECAUTIONS

NOTICE: Failure to follow these in-

structions will void the warranty.

• Wear gloves and safety glasses for protection

• Use extreme caution when using ladders or

when on roof tops

• Be aware of electrical wiring locations in walls

and ceilings

The following actions will void the warranty on

this product:

• Installation of any damaged venting component

• Unauthorized modification of the venting sys-

tem (Do not cut or alter vent components)

• Installation of any component part not manu-

factured or approved by DESA.

• Installation other than as instructed by these

instructions

WARNING: Read all instruc-

tions completely and thoroughly

before attempting installation.

Failure to do so could result in

serious injury, property damage

or loss of life.

WARNING: B-type vent pipe air-

space clearance to combustibles

is 1" on all sides. Where the vent

pipe passes through a vertical wall

a listed thimble approved for use

with B-type vent must be used.

VENTING INSTALLATION

A 4" B-type venting system must be connected to the

appliance for venting to the outside of the building.

The following section is provided as a guide to

install a standard B-type vent installation.

Standing code requirements concerning B-type

vent installations may vary within your state,

province or local codes jurisdiction. Therefore,

it is recommended that you check with your local

building code authority for specific requirements

or in absence of local codes, follow Section 7.0

of the current National Fuel Gas Code NFPA

54/ANSI Z223.1 or in Canada with CAN/CSA

B149 for Category I systems using double wall

B-1 vent pipe.

This gas appliance must be vented to the outdoors

only and may not be terminated into an attic space

or into a chimney flue servicing a solid fuel burn-

ing appliance.