2.2 Superheat INPUT FORM
Inputs

SH Table

(Superheat Table) Select Standard or Custom. Standard calcu-

lates the Target Superheat using charts from California's Title 24. Cus-

tom allows the technician to enter in the Target Superheat.

Target SH (

Target Superheat) if you selected Custom on SH Table and then

type in the Manufacturer's recommended superheat in the Target SH

input.

Refrigerant

Select from the 44 Refrigerants available.

OD Dry Bulb

(Outdoor Dry Bulb) Air temperature going into the con-

denser. Suggested Accessories: ATH4, ATA1.

Return WB

(Return Wet Bulb) Take the wet bulb temperature at the inlet

of the evaporator. Generally right before the filter is a good location.

Suggested Accessories: ATH4, ATWB1.

SL Pressure

(Suction Line Pressure) Pressure of the suction line taken at

the suction line service port. Suggested Accessories: ASX14.

SL Temp

(Suction Line Temperature) Take the suction line temperature be-

tween the evaporator and compressor. Make sure to be at least 6 inches

away from the compressor. Suggested Accessories: ATC1.

Customer ID

Used in the file name to save, recall and download tests. Use

arrow buttons to "type" in each character. Press RIGHT arrow to get to

the first character. Once complete, press ENTER to lock it in.

Units

Select English or Metric units

Superheat INPUT FORM using the Standard superheat table

from Title 24.

Superheat INPUT FORM using the Custom superheat table

which allows the technician to enter in the manufacturer's

recommended superheat.

Use the arrows to type in

each character.

Press right arrow then

UP/DOWN arrows to switch

to Custom to enter

the manufacturer's

recommended superheat.

Use arrows to manually

enter in manufacturer's

recommended superheat.

Units can be changed to

either English or Metric.

Highlight input and press

Enter to see the list of

refrigerants. Scroll to desired

refrigerant. Press Enter to

lock it in.

Take measurements using

Fieldpiece Accessory Heads

or manual entry.