Advanced Operations

Units

On every INPUT FORM there is a “Units” line. The default is English

units. Metric units can be used by pressing the RIGHT arrow when “Units”

is highlighted. Scroll UP or DOWN to toggle between English and Metric

units. Press ENTER to lock in your selection. The HVAC Guide will convert

any measurement you have taken when units are changed mid test. The units

change is universal throughout all switch positions.

Saving Data

Press the SAVE button and press ENTER while Yes is highlighted when

in an INPUT FORM to save test data. Test data is saved along with Customer

ID and a time stamp. You will be prompted to input a Customer ID before

saving.

Recalling Saved Tests

While in the desired test, press the RECALL button to access previously

saved test data. Highlight the Customer ID from the list, and press ENTER,

and then highlight the date and time of the test you wish to recall, and press

ENTER again. The INPUT FORM for that switch position will then be popu-

lated with the previous test’s data. No Outputs are saved on the HVAC Guide,

they are simply recalculated from the saved inputs.

Contrast Adjustment

To adjust the contrast level of the display hold the BACKLIGHT button

until the Contrast Adjustment Screen shows. Press UP and DOWN arrows to

adjust, and ENTER to set.

Clearing a Single Input or INPUT FORM

Press CLEAR when an input is highlighted to erase a single input. Hold

the CLEAR button for three seconds and select Yes to clear an entire INPUT

FORM.

Features

Dot matrix display mode (128 x 64 dot)

Scrolling display

Mini USB to USB

Plug for use with an AC/DC adapter for prolonged data logging

Adapter details: Output (12V DC 150mA)

Wireless transmitter and receiver

Input types: drop down menu, accessory head directly, manual,

wireless (examples: Accessory head + ET2W/EH4W, SDP2, SC57,

SMAN4, SMAN440, SMAN460, etc.)

Display contrast adjustment

Firmware updates through PC software

Windows PC compatible

Output reports in Microsoft Excel

TM

format (.xls)

Blue Backlight

Test Data Diagnosis:

·

Target Evaporator Exit Temperature

·

Superheat Analysis

·

Subcooling Analysis

·

Combustion Analysis

·

CheckMe!® Analysis

·

Data Logger

· Display

· CFM

·

Charging Jacket

Data Record:

·

Customer ID/Time

·

Time (Date/Time Setting)

·

Accessing Saved Tests

·