The CheckMe!® test is included on model HG2 and HG3. It is available

for purchase on model HG1.

CheckMe!® evaluation was developed by Proctor Engineering Group and

is the most advanced real-world method for troubleshooting A/C systems.

It looks at the big picture to diagnose problems. Superheat, Subcooling, and

Target Evaporator Exit Temperature tests look at individual performance in-

dicators to determine if they are within proper range. CheckMe!® looks at the

system as a whole to give a more complete diagnosis. CheckMe!® saves time

and money by quickly diagnosing a range of potential problems or even mul-

tiple problems. CheckMe!® recommends actions to tune the air conditioner

or heat pump to its optimum performance with minimal retests. This leads

to even fewer call backs.

The algorithms built into CheckMe!® are based on the real world test data

of over 250,000 air conditioners. The testing procedure and accuracy of the

diagnosis have been refined over many years by Proctor Engineering. The

CheckMe!® switch position is a real time-saver because it can give you a more

accurate diagnosis than looking at individual aspects of the air conditioner.

Great way to avoid call-backs.

The CheckMe!® position has diagnoses that will help you pinpoint prob-

lems with the system. Besides providing better diagnoses, it also checks the

test numbers and warns you if there is a likely testing error. In these cases,

you will want to retake some measurements.

CheckMe!® in the HG3 will analyze with almost any amount of data.

The more information supplied, the more accurate and comprehensive the

diagnoses. CheckMe!® determines the current state of the equipment. It is

recommended that you pretest before repairs and test after repairs to confirm

the improvement.

5.2 CheckMe!® INPUT FORM

Below is a picture of the extended CheckMe! INPUT FORM. The fol-

lowing sections cover each part of the INPUT FORM in more detail. Refer

to the page numbers in the blue boxes.

Clear

Input

Output

Sync

Recall

Enter

Save

MAX 30VDC

24VAC

CONNECT ONLY TO

ACCESSORY HEADS!

HVAC Guide

Fieldpiece

HG3

SETUP

Target

Evaporator

Logger

Light

Exit Temp

CFM

Display

Superheat

Subcooling

Combustion

CheckMe!

Data

Service

Clear

Input

Output

Sync

Recall

Enter

Save

MAX 30VDC

24VAC

CONNECT ONLY TO

ACCESSORY HEADS!

HVAC Guide

Fieldpiece

HG3

SETUP

Target

Evaporator

Logger

Light

Exit Temp

CFM

Display

Superheat

Subcooling

Combustion

CheckMe!

Data

Service

INPUT FORM

Sys Type

:AC

Grant and Sys Info:

None

INDOOR UNIT

Meter Device:TXV/EXV

Return DB:

71.7˙F

Return WB:

60.8˙F

Supply DB:

52.3˙F

OUTDOOR UNIT

Refrigerant:R-22

Rated Amps:

17.0A

Target Subcool:

12˙F

SL Pressure: 58.0psig

SL Temp:

42.2˙F

LL Pressure: 220.1psig

LL Temp:

90.1˙F

OD Dry Bulb:

86.0˙F

Cond Amps Draw: 16.0A

TRUE FLOW:No

CustomerID:__JONES123

Units:English

12/31/2011 11:59PM

OUTPUT FORM

Low airflow, increase

airflow until actual

temp split matches

target temp split.

Actual temp split is

19.4˙F and target

temp split is

18.2˙F.

See Section:5.404

Overcharged, recover

refrigerant until

actual subcooling

reaches target

subcooling.

Actual subcooling is

17.9˙F and target

subcooling is 12.0˙F

See Sections:5.511

Condenser airflow OK.

See Sections: 5.701

Select the system type.

Options include: A/C, Heat

Pump or Geothermal. Page 42.

Generally used for utility

programs. See page 42.

All the parameters taken from

the Indoor Unit. Page 43.

All the parameters taken from

the Outdoor Unit. Page 44.

Trueflow is taken with a

TrueFlow grid. It's not used

with most utility programs.

It can be toggled on or off.

Page 43.

Enter the Customer ID using

the arrow buttons.

CheckMe! ® INPUT FORM.