3 motor cartridge subassembly, qx-1 thru 5, 1 motor cartridge subassembly removal, qx-1 thru 5 – Flowserve QX Limitorque User Manual

Page 27

Advertising
background image

27

Limitorque QX Electronic Actuator FCD LMENIM3314-00 – 5/11

flowserve.com

4.2.2 Handwheel Cover Assembly Remounting

Step 1

Lightly lubricate ‘O’-ring (#15-2) and install around handwheel cover subassembly pilot (#10). Slide ball bearing
(#9-13) back on end of clutch assembly if bearing was removed. Slide handwheel cover assembly pilot (#10) into the
unit housing assuring the ball bearing aligns in handwheel shaft bore and dowel pin (13-1) aligns with the pin hole in
cover.

NOTE:

for QX-3,4 and 5 Handwheel assembly must also align with Ball bearing (#9-3) and the idle shaft assembly, see

Figure 4.10 for view of idle shaft assembly location.

Step 2

Fit the 3 screws (#13-3) into handwheel cover mounting holes and tighten.

Check to make sure handwheel rotates freely.

4.3 Motor Cartridge Subassembly, QX-1 thru 5.

NOTE

: Sections 4.2 – 4.8 require the actuator to be removed from the mounting plate and the oil drained.

4.3.1 Motor Cartridge Subassembly Removal, QX-1 thru 5.

Table 4.7 Motor Cartridge Assembly Removal

ITEM NUMBER

DESCRIPTION

QTY.

5

MOTOR CARTRIDGE

1

9-1

TAB, BRACKET

1

9-2

SOCKET HEAD CAP SCREW

1

Figure 4.8 - Motor Cartridge Assembly Removal

Step 1

Using a M3 hex key, remove the M4 screw (#9-2) and bracket (#9-1). Grab end of motor cartridge shaft and pull out
cartridge subassembly.

Advertising