Limitorque QX Electronic Actuator FCD LMENIM3314-00 – 5/11

54

6

Electronic Assemblies

6.1 Terminal Cover

Table 6.1 - Terminal Cover Assembly

ITEM NUMBER

DESCRIPTION

QTY.

15-5

TERMINAL COVER SUBASSEMBLY

1

15-6

SOCKET HEAD CAP SCREWS

3

Figure 6.1 - Terminal Cover Assembly

6.1.1 Terminal Cover Removal
c

WARNING: Hazardous Voltage! Turn off all power sources to actuator before removing control module

assembly. Power sources may include main power or control power.

a

CAUTION: Potential to cause electrostatic damage to electronic components. Before handling electronic
components, ensure that you are discharged of static electricity by briefly touching a grounded metal object.

Step 1

Using a M6 hex key, remove the four M8 screws (#15-6) that mount the Terminal cover subassembly and remove
cover (#15-5).

Advertising