5 pipe plug, 6 baseplate, 1 baseplate removal – Flowserve QX Limitorque User Manual

Page 35

Advertising
background image

35

Limitorque QX Electronic Actuator FCD LMENIM3314-00 – 5/11

flowserve.com

4.5 Pipe Plug

NOTE:

Sections 4.2 – 4.8 require the actuator to be removed from the mounting plate and the oil drained.

Table 4.14 - Pipe Plug

ITEM NUMBER

DESCRIPTION

QTY.

12-1

PIPE PLUG

1

Figure 4.17 Pipe Plug

NOTE:

If the pipe plug was removed, pipe sealant or tape must be applied to plug threads before remounting.

4.6 Baseplate

4.6.1 Baseplate Removal

NOTE:

Sections 4.2 – 4.8 require the actuator to be removed from the mounting plate and the oil drained.

NOTE:

If unit has a F/FA-05 or 07 QX-1 & 2, F/FA-10 QX-3 thru 5 base or Thrust base attached, these bases must be

removed before removing the standard baseplate. See section 4-9 thru 4-10.