1 control module removal, 2 control module subassemblies – Flowserve QX Limitorque User Manual
Page 58
Limitorque QX Electronic Actuator FCD LMENIM3314-00 – 5/11
58
Figure 6.5 - Control Module Assembly
6.3.1 Control Module Removal
Step 1
Using a M3 hex key remove screw (# 14-12) and retainer (#14-11 ). Disconnect all wiring harnesses.
Step 2
Using a M3 hex key, loosen the three M4 mounting screws (#14-9) that mount the Control module subassembly.
Slightly rotate the complete control module subassembly in a counterclockwise (CCW) direction until the keyholes
slots in the control module chassis plate (#1-1) allow the head of the screws to pass thru and remove controls
subassembly.
6.3.2 Control Module Subassemblies
Table 6.6 - Low Voltage (Less than 250 VAC) Control Module Subassembly
ITEM NUMBER
DESCRIPTION
QTY.
1-1
CHASSIS PLATE
1
1-2
MOTOR CONTROLLER BOARD
1
1-7
SHIELD
1
1-8
PAN HEAD CAP SCREW
4
1-9
COVER, IRAM
1
1-10
RIBBON CABLE
1