2 motor cartridge assembly remounting – Flowserve QX Limitorque User Manual

Page 28

Advertising
background image

Limitorque QX Electronic Actuator FCD LMENIM3314-00 – 5/11

28

Table 4.8 - Motor Cartridge Subassembly, Item 5

ITEM NUMBER

DESCRIPTION

QTY.

5-1

BUSHING

1

5-2

BALL BEARING

2

5-3

OIL SEAL

1

5-4

SHAFT

1

5-5

SPIRAL PIN

1

5-6

PINION, MOTOR

1

5-7

SPIRAL PIN

1

5-8

'O'-RING

1

Figure 4.9 - Motor Cartridge Subassembly, Item 5

4.3.2 Motor Cartridge Assembly Remounting.

Step 1

Lightly lubricate ‘O’-ring (#5-8). Push cartridge subassembly into housing bore assuring motor pinion (#5-6) aligns
with motor gear on handwheel side of housing. Cartridge face should be even or below the counter bore face in the
unit housing. Place bracket (#9-1) and screw (#9-2) in countered bored area with M4 tap and tighten screw. Note: The
bracket must sit flat on cartridge bushing and on the housing counter bore face.