Warning notices
inside the device

Inside of device:

Setup regulations

Ensure an adequate supply of fresh air during charging. Set up the device at
least 0.5 m (1 ft. 7.69 in.) above the floor.
The charger can cause DC fault currents in the ground conductor. If a fault cur-
rent protection device (RCD) is used on the mains side to protect against electric
shock, it must conform to Type B.
Do not dispose of used chargers with domestic waste. Dispose of them accord-
ing to safety rules.

WARNING! An electric shock can be fatal. The housing may only be opened by
a service engineer who has been trained by the manufacturer. The device must
be disconnected from the mains before starting any work with the housing
opened. A suitable measuring instrument must be used to ensure that electrically-
charged components (e.g. capacitors) are fully discharged. Use an easily legible
and understandable warning sign to ensure that the device is not reconnected to
the mains supply before all the work has been completed.

(4)
(5)

(+)
( - )

(1)
(2)
(3)

RCS 3.0

Lights

1
2
3
4

12V
GREEN
YELLOW
RED
BLUE

+/-

Temp. Sensor
Ext. Start/Stop

WARNING

Hazardous Voltage

Kondensator Entladezeit < 2 min.

Capacitor discharge time < 2 min.

Décharge de condensateur < 2 min.

Risk of Electric Shock!
Do not operate at circuits
more than 250 V to ground!

0... 30V

DC/4A

0... 250V

AC/4A

Use Copper Conductors Only!

C Common
NC Normally Closed
NO Normally Opened
L Line
N Neutral

Wire

max. 1A

AC Output!

42,0409,0008

C NC NO

C NC NO

C NC NO

L/C NC NO N

WARNING!

WARNING! If one of these devices falls or topples over, it could cause serious or
even fatal injury. Make sure that all system components are securely in position
when setting them up. If using a floor bracket or wall bracket, always make sure
that all the securing elements are seated securely.