The individual selection options are explained in greater detail below:

The following settings are available for electrolyte circulation:
-

Off:
-

Electrolyte circulation switched off

-

Continuous:
-

Electrolyte circulation permanently on

-

Program 1 to 5:
-

Default electrolyte circulation programs

-

More information on the programs can be found under "Electrolyte circulation" in
the "Options" section

-

Automatic:
-

Automatic adjustment of the electrolyte circulation as dictated by the situation

-

"User" - "On"/"Off":
-

Individual setting of the electrolyte circulation

-

The settings for "On" and "Off" determine the pulse/pause ratio of the air flow in-
tervals

The following settings are available for temperature-controlled charging:
-

automatic/OFF/required:
-

automatic ... Temperature-dependent adjustment of the charging characteristic

-

OFF ... The measured battery temperature is not taken into account

-

required ...
Charging only starts when a temperature sensor is connected

A list appears with the following selection options:

Electrolyte circulation ("Air Pump"):

Temperature-controlled charging: