6 command list – FSR DV-HMSW-88 8x8 MATRIX User Manual

Page 15

Advertising
background image

15

6 Command List:

CON

Connect input to output(s)

EDID

EDID setting

RST

Reset DV-HMSW-88

STAT

Universal Status command


NOTE:

All commands are terminated with a carriage return (0Dhex) represented by <cr>

The default baud rate is 38400 bps.

6.1 Set CON Command

Tells the DV-HMSW-88 which outputs to connect to which input
CON id input “(“ output “,” output “,” ……”)”[“;” input”(“output,,,,”)”] <cr>

WHERE:

CON

3 ASCII byte command name

id

2 byte unit ID

input

An input number between 1 – 8

“(“

Parentheses indicating the start of the outputs to connect the input to.

output

an output number 1 – 8 to connect to the input, zero representing no input. Multiple outputs can be
included in the list separated by a comma.

“)”

Parentheses to end the list of outputs

“;”

Delimiter separating additional definitions

<cr>

Carriage Return (0Dhex)


Example:
Connect Unit 01 input 1 to outputs 2, 3 and 4 and input 2 to output 1.
CON 01 1(2,3,4); 2(1)<cr>

6.2 Set

HDMI

EDID

Tells the unit which timing scheme to use.

EDID id output setting[“;” output setting]<cr>
EDID

HDMI EDID command

id

2 byte unit ID

output OUTPUT number 1 – 8

setting

“;” Delimiter separating additional definitions
<cr>

Carriage Return (0Dhex)

Example:
Unit 01 Save EDID Data of Output 1 to Input 2,3,4, And Output 2 to Input 5,6
EDID 01 1(2,3,4); 2 (5,6)<cr>

Advertising