Model 13353, 13363, and 13373 Addressable Amplified Speakers

Page 19 of 52

e:\radio products-current release\43004\43004-034f\43004-034f.doc
03/15

The following screen will be displayed when adding a new archive:

1. Enter an Archive Description

for the paging module archive as shown above. The description is

generally the device’s location within the end-user’s facility or a tag number identification assigned
by the system installer.

2. Enter the Customer/Site description. This is generally the facility name. This entry is useful when

managing speakers at multiple facilities. It will allow the system administrator to easily sort the
speaker entries when making changes or updates to the speaker programming.

3. Select the archive creation Method using the radio buttons. To upload an existing configuration

from the connected speaker, select Create new unit

archive by reading connected unit

.

When programming an older series Addressable Amplified Speaker (Models 13352, 13362, 13372)
using Card Suite Version 4.2.0 or newer, a new archive should be created only by first reading the
connected speaker. Using the default values setting will display programming features that do not
exist in old series models.

If a speaker is not connected or the programmer wants to create a new archive starting with default
values, select: Create new unit archive using default values.

4. Select OK. The archive will be created and then opened for editing. (The “reading connected unit”

creation requires about 15 seconds.)