GAI-Tronics 13363 Addressable Amplified Speakers Installation and Operation Manual User Manual

Page 57

Advertising
background image

Pub. 43004-034F

Model 13353, 13363, and 13373 Addressable Amplified Speakers

Page 52 of 52

e:\radio products-current release\43004\43004-034f\43004-034f.doc
03/15

CARD Suite Information for Addressable Amplified Speaker No. 4:

In this example, Addressable Amplified Speaker No. 4 is part of the East Campus and Dorm Zone areas
and can be accessed via addresses 104#, 112#, 113# and 99#. If any other code is entered, Speaker 4 will
remain inactive. Other notable programmed parameters for this speaker are:

 Addresses 104, 112, and 113 will provide a contact closure output when active, but it will deactivate

within a few seconds after the broadcast has ceased.

 Address 99 (All Call) will also provide a contact closure output when active, but the closure will

remain active for 3.00 seconds after the broadcast has ceased.

 Low Battery Alert is not activated.
 It is programmed for Voice Switch Mode with a voice switch silence limit programmed for 5

seconds.

 Automatic Level Adjustment is disabled.