Specifications – Gasboy MCE300 User Manual
Page 62

03/07/03
12-1
Section 11
SPECIFICATIONS
CHARACTERISTICS
Dimensions:
MCE
300
13"
L x 11" W x 3 5/8" H
MCE 300HE
15 1/4 L x 8 1/2" W x 5" H
Weight: MCE 300 10 lbs.; MCE 300HE 13 lbs., 4 oz.
Power Requirements: MCE 300: 115 VAC + 10%, 47-63HZ, 30 watts maximum
MCE 300HE 115 VAC + 10%, 47-63HZ, 55 watts maximum
Environmental Requirements:
Operating:
10
o
to 40
o
C., 20% to 90% R.H. (Non-condensing)
Unit should be located in a clean office-type environment for maximum life.
Storage: -20
o
to 70
o
C., 20% to 90% R.H.
There should be no functional failure after 12 hours from returning to standard
conditions.
Approvals: FCC
Memory: 8K RAM, battery backed (5 year retention)
Communication: 2 Asynchronous ports, both are RS-232 compatible
Baud Rates: 300, 600, 1200, 2400, 4800, 9600
Encoder:
Write/Read Function: ABA Track 2
Transport Mechanism: Motorized Forward and Reverse Control
Life: 500,000 passes