Gasboy Enhanced Communications User Manual
Page 18

Site Installation Review and Considerations
Page 18
MDE-4520C Enhanced Communications Installation Manual · February 2008
Connections between the Wireless Modem and an Islander
To use the wireless modem with the Islander, you must configure the remote port to be either
port 1 or port 3 (
). The Islander CPU K1 (port 1) or K2 (port 3) jumper patch and the
jumpers (K1 or K2) on the Site Communications I/O board must be configured as shown in
On the Site Communications I/O PCA, K3 (for port 1) or K4 (for port 3) should not be
jumpered. A C07263 cable (included with the M06544K001 kit) must be installed on the Site
Communications I/O PCA that controls ports 1 and 3. This cable will connect to P10 and pins
6 through 10 of P3 (port 1) or P4 (port 3).
Figure 9: Wireless Modem to Islander Connections
Wireless Modem
Terminal Block
1
2
3
4
5
6
7
Port 1 (TB5)
or
Port 3 (TB6)
1
2 3
4
5
Figure 10: Jumper Configurations
Site CPU PCA K1 or K2
0
1
2
3
4
5
6
7
8
9
A
1
2
3
Site Communication I/O PCA K1 or K2
1
2
3
4
5
6
8
7