Figure 18, Figure 19, Figure 20 – Gasboy Enhanced Communications User Manual
Page 31: Cfn 3 connection, Rs-232 pc connection

MDE-4520C Enhanced Communications Installation Manual · February 2008
Page 31
Serial-to-LAN Connection Installation
Figure 18: RS-232 D-Type Connector
1
2
3
4
5
TXD
DTR
RXD
CD
GND
100 FEET MAX.
P/N C05758
2
20
3
8
7
1
13
14
25
MALE CONNECTOR
(WIRE END VIEW)
Figure 19: RS-232 Gasboy Termination Box
1
2
3
4
5
TXD
DTR
RXD
CD
GND
100 FEET MAX.
1
2
3
4
5
GASBOY
RS232
MODEM CABLE
P/N C04532
Serial-to-LAN Adapter
(see
on
)
C05769
Figure 20: RS-422 Gasboy Short Haul Modem
1500 FEET MAX.
1
2
3
4
5
System
Ground
TX+
TX-
RX+
RX-
P/N C05618
1
2
3
4
GASBOY
SHM
MODEM CABLE
P/N C04532
Serial-to-LAN Adapter
AC
POWER
(see
CFN 3 Connection
To connect to a CFN 3, use a C05995 modem cable from Port 4, 5, or 6 of the CFN 3 to the
serial-to-LAN adapter.
RS-232 PC Connection
To connect the adapter to a serial port of a PC, use a standard PC-to-modem cable