Gasboy FuelOmat Payment Terminal User Manual
Page 73

OrPT Manual
63
6-2.3. Module and Associated Modules Status Messages
The OrPT and associated modules status messages concern errors in the OrPT operation and the
modules linked to it such as the outdoor printer.
The following messages are examples. The messages text is determined in the Station Controller at
the Setup phase of the SiteOmat. Therefore, there may be some difference in context.
Example 1:
No communication
N O C O M M U N I C A T I O N
Figure 6-3. No Communication Message
Corrective Action: Check communication connections, check µVIT LEDs status, and check
link
status.
Example 2:
No printout
P R I N T E R L O W
I N P A P E R
Figure 6-4. No Paper in Printer Message
Corrective Action: Check paper in printer, check printer LEDs
Example 3:
Pump failure
P u m p i n u s e
Figure 6-5. Pump Fail Message
Corrective Action: Check pump, it might be used.