Encoder with Profibus interface

14

10.1 Parameters
The manufacturer-specific parameters are described below� The parameters to the

encoder profile (also supported) are described in chapter 9�
10.1.1 Activation of the manufacturer-specific parameters
The manufacturer-specific parameter byte 26 is activated via bit 6 in octet 9�

The manufacturer-specific bytes 27���39 are activated in byte 26�

Octet 9 bit 6

Octet 26

0

Deactivated

1

Activated

Octet 26 bit 7

Octet 27...29

0

Deactivated

1

Activated

10.1.2 Requested measuring steps
The device can be programmed with the [Desired measuring units] parameter so

that any number of measuring steps referred to

– one revolution

– the entire measuring range

– any part of the measuring range

can be implemented�

Octet

10

11

12

13

Bit

31���24

23���16

15���8

7���0

Data

2

31

to 2

2

4

2

23

to 2

16

2

15

to 2

8

2

7

to 2

0

Required number of measuring steps