9 unit of measurement velocity, 2 data exchange during normal operation – ifm electronic RN3001 User Manual

Page 19

Advertising
background image

UK

Encoder with Profibus interface

19

10.1.9 Unit of measurement velocity
The unit for the velocity value to be provided (class ifm 2�2) can be set via this

parameter�

Unit

Bit 4

Bit 5

Steps / second

0

0

Steps / 100ms

1

0

Steps/10ms

0

1

Revolutions / minute

1

1

10.2 Data exchange during normal operation
The process actual value is in general transferred as a 32-bit word (double word)

with the manufacturer-specific encoder classes ifm 2�1 and ifm 2�2� In addition to

the 25 bits that are provided for the position value 7 other bits are used as status

bits� In the (peripheral) output double word the master sends the preset value and

in addition the control bits to the encoder�
For encoders of this type more than 25-bit absolute position data may be available�

The position values < 25 bits are not supported in the ifm classes; the more

significant bits are overwritten by status bits�

If the ifm classes are to be used with encoders whose physical resolution exceeds

25 bits, the user must ensure that the physical position value is scaled to a (max�)

output value < 33554432 (via parameter setting)� If absolute values > 25 bits are

required, Class 2 has to be selected�
An additional (peripheral) input word of the current velocity value is transferred

with device class ifm 2�2�

Identifica-

tion

F1 hex

D0 hex

Encoder →

master

Status + position actual value

Velocity

Status + 2

24

2

23

- 2

16

2

15

- 2

8

2

7

- 2

0

2

15

- 2

8

2

7

- 2

0

Master →

encoder

Preset value + control bits

Control + 2

24

2

23

- 2

16

2

15

- 2

8

2

7

- 2

0

Advertising