14 serial number, 12 led indicators, 1 legend – ifm electronic RN3001 User Manual

Page 27

Advertising
background image

UK

Encoder with Profibus interface

27

11.2.14 Serial number
According to the encoder profile, diagnostic bytes 48���57 are intended for a serial

number� At the moment the serial number is not stored in the device; the bytes are

pre-assigned with 2A hex�

12 LED indicators

12.1 Legend

LED on / lit

The terminal cap has two LEDs that optically represent

the bus status on the encoder�

The red LED is used to display errors; the green LED to

display the status of the encoder� Each LED has three

states: off, on, flashing� Seven of the nine possible com-

binations are used to display a certain state�
Should there be problems during start-up of the device,

the status of the LEDs is to be checked; it often gives

information about the cause of the fault�

LED flashes

LED off

Colour

Status /

frequency

Colour

Status /

frequency

Description

Red

Green

No voltage supply

The encoder is operational but has not received any

configuration data after the voltage was applied�
Possible causes: Address incorrectly set; bus cables

incorrectly connected�

Parameter setting or configuration fault
The encoder receives configuration or parameter setting

data of an incorrect size or inconsistent data�
Possible cause: e�g� total resolution is set too high

The encoder is operational but is not addressed by the

master (e�g� incorrect address is addressed)�

The encoder does not receive any data for a longer

time (approx� 40 s) (e�g� data line interrupted)
Normal operation in the data exchange mode

Set-up in the data exchange mode