Installation instructions, Water supply, Notices – Paloma PHH-32 part 2 User Manual

Page 12: Notice, Plumbing, Water supply installation, Water supply connections (cont.)

Advertising
background image

48

INSTALLATION INSTRUCTIONS

Water Supply

Plumbing

Water Supply Installation

NOTICES:

Use only Teflon tape on all COLD and HOT water

connections.

If the water flow resistance of a showerhead is

too high, the burner in the water heater will fail to

ignite. Keep all showerheads clean from debris

that could cause additional pressure drop.

If using mixing valves on the outlet, choose

one that prevents COLD water pressure from

overcoming HOT water pressure.

If multiple water heaters are installed in a

manifold system, the water piping MUST be in

“parallel” and the water pressure at each water

heater should be 40 psi (276 kPa).

Install a COLD water shut-off valve near the

inlet line on the water heater. This valve will be

used for servicing and draining purposes.

NOTICE:

It is not recommended to

use pipes with smaller diameters than the water

supply connection of the water heater.

Before attaching the water line to the water

heater, open the shut-off valve. Run the water

until it has purged all contaminants (sand,

debris, air, caulking, etc.).

Install a service valve on the end of the COLD

water supply line and connect it to the water

inlet on the water heater.

To ensure proper operation of the water heater,

follow these water pressure guidelines.
Operation of the water heater requires a

minimum water pressure of 14 psi (97 kPa) and a

minimum water flow rate of 0.4 gpm (1.5 lpm).

Water pressure of 40 psi (276 kPa) is required to

achieve maximum flow rate.

To maintain proper performance, there must be

sufficient water supply pressure.

Required Water Pressure =

Min. Operating Water Pressure

(14 psi [97 kPa])

+ Pipe Pressure Loss

+ Faucet Pressure Loss

+ Safety Margin

(more than 5 psi [34 kPa]).

To supply HOT water to upper floors, additional

water pressure will be required (0.44 psi [3 kPa]

per foot of height). Calculate the distance

between the water inlet of the water heater

(ground level) to the HOT water faucet farthest

away from the water heater (upper floor level).

Well water systems should be set to ensure a

minimum system pressure of 40 psi (276 kPa).

The pressure should remain constant and stable

during the operation of the water heater.

• Gravity water pressure is not recommended.

When the water is supplied from a water supply

tank, the height of the tank, the diameter of the

supply pipes, and their relation to water pressure

need to be taken into consideration.